How Can We Help?
C3203 (bizhub 650i/550i/450i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C3203: Fusing motor torque failure |
Rank | C |
Trouble detection condition | When the printing ends, the fusing motor torque exceeds the predetermined value. |
Trouble isolation | – |
Relevant electrical parts | -Fusing motor (M3) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Check the connector between M3-BASEB CN19E for proper connection and correct as necessary.
- Check the connector of M3 for proper drive coupling and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- M3 load check
- Check code: 45
- Multi code: 1, 2, 3, 4, 6 (bizhub 650i), 1, 3, 4, 6 (bizhub 550i), 1, 2, 4, 6 (bizhub 450i)
- Control signal: BASEB CN19E-6 to 10
- Location of electrical component: 1-C
- Replace M3. (Part# AA2JM11100)
- Replace CPUB.
650i/550i(Part# AC74H02P03)
450i (Part# AC76H02P02) - Replace BASEB. (Part# AC74H02101)