How Can We Help?
C3204 (bizhub 950i/850i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C3304: Reverse paper cooling fan/2 failure to turn |
Rank | B |
Trouble detection condition | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | – Reverse paper cooling fan/2 (FM5) – Paper feed/transport drive board (PFTDB) |
Procedure
- Check the connector between FM5-relay CN700-relay CN280-relay CN271A-PFTDB CN27 for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- FM5 load check
- Check code: 42
- Multi code: 16, 17
- Control signal: PFTDB CN27-7 (LOCK)
- Location of electrical component: 7-P
- Replace FM5.
- PFTDB F41 conduction check.
- Replace PFTDB.