Trouble typeC3303: Paper cooling fan/out failure to turn
RankB
Trouble detection conditionThe fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts– Paper cooling fan/out (FM13)
– CPU board (CPUB)
– Base board (BASEB)

Procedure

  1. Check the connector between FM13-relay CN323-BASEB CN27E for proper connection and correct as necessary.
  2. Check the fan for possible overload and correct as necessary.
  3. Check CPUB for proper installation and correct as necessary.
  4. FM13 load check
    • Check code: 42
    • Multi code: 13
    • Control signal: BASEB CN27E<B>-10 (DRIVE), BASEB CN27E<B>-12 (LOCK)
    • Location of electrical component: 14-C
  5. Replace FM13.
  6. Replace CPUB.
  7. Replace BASEB.