Trouble type Switchback paper cooling fan/2 failure to turn
Trouble code C3304
Rank B
Detection timing The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts• Switchback paper cooling fan/2 (FM5)
• Paper feed/transport drive board (PFTDB)

  (2)Procedure

Step Action Control signal Location of electrical components
1 Check the connector between FM5-relay CN282-relay CN280-relay CN279-relay CN271B-PFTDB CN10 for proper connection and correct as necessary.
2 Check the fan for possible overload and correct as necessary.
3 FM5 operation check PFTDB CN10-8 (LOCK) 6-P
4 Replace FM5 (Taiwan Only)
5 PFTDB ICP9 conduction check
6 Replace PFTDB (Part# A2X0H00202)

Document Information ID D0001234387 Revise ID R000001