How Can We Help?

C3306 (bizhub C750i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC3306: Fusing edge cooling fan/Fr failure to turn
RankB
Trouble detection conditionThe fan lock signal remains Low for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts-Fusing edge cooling fan/Fr (FM21)
-CPU board (CPUB)
-Base board (BASEB)

Procedure

  1. Check the connector between FM21-relay CN162-relay CN161-BASEB CN22E for proper connection and correct as necessary.
  2. Check the fan for possible overload and correct as necessary.
  3. Check CPUB for proper installation and correct as necessary.
  4. FM21 load check
    • Check code: 42
    • Multi code: 19, 20
    • Control signal: BASEB CN22E-13 (REM), BASEB CN22E-15 (LOCK)
    • Location of electrical component: 12-C
  5. Replace FM21. AA7NM10H00
  6. Replace CPUB. (Part# ACKNH02P03)
  7. Replace BASEB.(Part# ACKNH02101)

(Link to the Field Service Manual)

Table of Contents