C3307 (bizhub 950i/850i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C3307: Fusing edge cooling fan/2 failure to turn |
Rank | B |
Trouble detection condition | The fan lock signal remains Low for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | – Fusing edge cooling fan/2 (FM27) – Paper feed/transport drive board (PFTDB) – CPU board (CPUB) – Base board (BASEB) |
Procedure
- Check the connector between FM27-relay CN832-relay CN166B-PFTDB CN31 for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- FM27 load check
- Check code: 42
- Multi code: 28
- Control signal: PFTDB CN31-4 (REM), PFTDB CN31-5 (LOCK)
- Location of electrical component: 4-P
- Replace FM27.
- PFTDB F22 conduction check.
- Replace PFTDB.
- Replace CPUB.
- Replace BASEB.