C3310 (bizhub 958/808)

You are here:

Contents

Trouble typeC3310: Output tray exhaust fan’s failure to turn (bizhub 958/808, bizhub PRO 958 only)
RankB
Trouble detection conditionThe fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts• Output tray exhaust fan (FM18)
• MFP board (MFPB)

 Procedure

  1. Check the connector between FM18-relay CN701-MFPB CN18E for proper connection and correct as necessary.
  2. Check the fan for possible overload and correct as necessary.
  3. FM18 operation check
    • Control signal: MFPB CN18E-8 (LOCK)
    • Location of electrical component: 16-K
  4. Replace FM18. ( A0P0M14200 )
  5. MFPB F7E conduction check
  6. Replace MFPB. ( A796H02003 )

NOTICE

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

(Link to the Field Service Manual) K.3.9.7.