Trouble typeC3425: Fusing warm-up trouble
RankA
Trouble detection condition-Detected temperature of the heating roller temperature sensor (TEMS) does not go up a given range of temperature even after a lapse of given period of time at warm up.

-The temperature detected by the heating roller temperature sensor (TEMS) does not shift from the pre-standby state even after the lapse of a predetermined period of time after the completion of warm-up.
Trouble isolation
Relevant electrical parts-Fusing unit
-Heating roller temperature sensor (TEMS)
-DC power supply (DCPU)
-CPU board (CPUB)
-Base board (BASEB)

Procedure

  1. Check the fusing unit for correct installation (whether it is secured in position).
  2. Check the open/close operation of the right door.
  3. Check the connector between the fusing unit-relay CN95, CN96-BASEB CN4E for proper connection and correct as necessary.
  4. Check the connector between BASEB CN2E-DCPU CN7 for proper connection and correct as necessary.
  5. Check CPUB for proper installation and correct as necessary.
  6. Replace the fusing unit.
    650i (Part# AA7NR70200)
    450i/550i (Part# AA7RR70700)
  7. Replace CPUB.
    650i/550i(Part# AC74H02P03)
    450i (Part# AC76H02P02)
  8. Replace BASEB. (Part# AC74H02101)
  9. Replace DCPU. (bizhub 650i/550i / bizhub 450i)
    bizhub 650i/550i (Part# AA7NR71600)

(Link to the Field Service Manual)