How Can We Help?

C3425 (bizhub C360i/C300i/C250i)

You are here:

Contents

Trouble typeC3425: Fusing warm-up trouble
RankA
Trouble detection condition• Detected temperature of the heating roller temperature sensor (TEMS) does not go up a given range of temperature even after a lapse of given period of time at warm up.
• The temperature detected by the heating roller temperature sensor (TEMS) does not shift from the pre-standby state even after the lapse of a predetermined period of time after the completion of warm-up.
Trouble isolation
Relevant electrical parts• Fusing unitHeating roller temperature sensor (TEMS)
• DC power supply (DCPU)
• CPU board (CPUB)
• Base board (BASEB)

Procedure

  1. Check the fusing unit for correct installation (whether it is secured in position).
  2. Check the open/close operation of the right door.
  3. Check the connector between the fusing unit-relay CN95, CN96-BASEB CN4E for proper connection and correct as necessary.
  4. Check the connector between BASEB CN2E-DCPU CN9 for proper connection and correct as necessary.
  5. Check CPUB for proper installation and correct as necessary.
  6. Replace the fusing unit. (Part# AA2JR70300)
  7. Replace CPUB. (Part# AA2JH02N06)
  8. Replace BASEB. (Part# AA2JH02005)
  9. Replace DCPU. (Part# AA2JR70600)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.9.4 (Link to the Field Service Manual)

Table of Contents