C3425 (bizhub C360i/C300i/C250i)
Contents
Trouble type | C3425: Fusing warm-up trouble |
Rank | A |
Trouble detection condition | • Detected temperature of the heating roller temperature sensor (TEMS) does not go up a given range of temperature even after a lapse of given period of time at warm up. • The temperature detected by the heating roller temperature sensor (TEMS) does not shift from the pre-standby state even after the lapse of a predetermined period of time after the completion of warm-up. |
Trouble isolation | – |
Relevant electrical parts | • Fusing unitHeating roller temperature sensor (TEMS) • DC power supply (DCPU) • CPU board (CPUB) • Base board (BASEB) |
Procedure
- Check the fusing unit for correct installation (whether it is secured in position).
- Check the open/close operation of the right door.
- Check the connector between the fusing unit-relay CN95, CN96-BASEB CN4E for proper connection and correct as necessary.
- Check the connector between BASEB CN2E-DCPU CN9 for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Replace the fusing unit. (Part# AA2JR70300)
- Replace CPUB. (Part# AA2JH02N06)
- Replace BASEB. (Part# AA2JH02005)
- Replace DCPU. (Part# AA2JR70600)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.9.4 (Link to the Field Service Manual)