Trouble typeFusing warm-up trouble
Trouble codeC3425
RankA
Detection timing-Detected temperature of the heating roller temperature sensor (TEMS) does not go up a given range of temperature even after a lapse of given period of time at warm up.
-The warm-up is not completed even after the set period of time has elapsed after the warm-up is started.
-Less than the predetermined temperature of the heating roller temperature sensor (TEMS), even after a predetermined period of time after warm-up is complete.
Trouble isolation
Relevant electrical parts-Fusing unit
-Heating roller temperature sensor (TEMS)
-DC power supply (DCPU)
-Printer control board (PRCB)

(2)Procedure

StepActionControl signalLocation of electrical components
1Check the fusing unit for correct installation (whether it is secured in position).
2Check the open/close operation of the right door.
3Check the fusing unit, DCPU and PRCB for proper connection and correct or change as necessary.
4Replace the fusing unit (Part# A161R71877)
5Replace PRCB (Part# A161H00108)
6Replace DCPU (Part# A161R7A100)
  • Link to the layout drawings for related parts by each trouble code (S.60. C3425)

K3.8.4 (Link to the Field Service Manual)