Trouble typeFusing warm-up trouble
Trouble codeC3425
RankA
Detection timingAfter warm-up operation starts, the heating roller temperature sensor does not detect a temperature as high as a predetermined one though a predetermined period of time has elapsed.
Trouble isolation
Relevant electrical parts-Fusing unit
-Heating roller temperature sensor (TEMS2)
-IH power supply (IHPU)
-Noise filter (NF1)
-Printer control board (PRCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the fusing unit for correct installation (whether it is secured in position).
2Check the open/close operation of the upper right door.
3Check the fusing unit, IHPU, NF1 and PRCB for proper connection and correct or change as necessary.
4Replace the fusing unit (Part# A2X0R71011)
5Replace IHPU (Part# A61DM40A00)
6Replace PRCB (Part# A2X0H00102)
7Replace NF1 (Part# A2XKM40J00)

K.3.8.6 (Link to the Field Service Manual)