C3723 (bizhub 958/808)

You are here:

Contents

Trouble typeC3723: Fusing abnormally high temperature detection (pressure) (bizhub 958, bizhub PRO 958 only)
RankA
Trouble detection conditionDetected temperature of the pressure roller thermistor/2 (TH3) goes beyond a given temperature for a given period of time consecutively.
Trouble isolation
Relevant electrical parts• Fusing unit
• Pressure roller thermistor/2 (TH3)
• IH power supply unit (IHPU)
• Noise filter (NF1)
• Pressure roller power supply unit (PRPU)
• MFP board (MFPB)

 Procedure

  1. Check the fusing unit for correct installation (whether it is secured in position).
  2. Check the open/close operation of the upper right door.
  3. Check the fusing unit-MFPB CN30E for proper connection and correct or change as necessary.
  4. Check the connector between NF1 CN2-IHPU CN1 for proper connection and correct as necessary.
  5. Check the connector between IHPU CN8-MFPB CN18E for proper connection and correct as necessary.
  6. Replace the fusing unit. ( 958)A796R71422 )( 808)A795R72922 )
  7. Replace IHPU. (958)( A796M40B00 )(808)( A8KNM40A02 )
  8. Replace PRPU. ( A796M40500 )
  9. Replace MFPB. ( A796H02003)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

(Link to the Field Service Manual) K.3.9.11.