C3725 – (bizhub 364e/284e/224e)

You are here:

Contents

Trouble typeFusing abnormally high temperature detection (Main of the heating side)
Trouble codeC3725
RankA
Detection timing• Detected temperature of the heating roller temperature sensor (TEMS) goes beyond a given temperature for a given period of time consecutively.
• The hard protector signal error is detected for a given period of time consecutively.
Trouble isolation
Relevant electrical parts• Fusing unit
• Heating roller temperature sensor (TEMS)
• Printer control board (PRCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the fusing unit for correct installation (whether it is secured in position).
2Check the open/close operation of the right door.
3Check the fusing unit and PRCB for proper connection and correct or change as necessary.
4Replace the fusing unit (Part# A161R71877)
5Replace PRCB (Part# A61FH00101)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.8.5 (Link to the Field Service Manual)