C3725 (bizhub 558/458)
Contents
| Trouble type | C3725: Fusing abnormally high temperature detection (Main of the heating side) | 
| Rank | A | 
| Trouble detection condition | Detected temperature of the heating roller temperature sensor 1 (TEMS/1) or heating roller temperature sensor (TEMS) goes beyond a given temperature for a given period of time consecutively. | 
| Trouble isolation | – | 
| Relevant electrical parts | • Fusing unit  • (bizhub 558): Heating roller temperature sensor 1 (TEMS/1) • (bizhub 458): Heating roller temperature sensor (TEMS) • IH power supply (IHPU) (bizhub 558 only) • Fusing power supply (FUPU) (bizhub 458 only) • MFP board (MFPB)  | 
Procedure
- Check the fusing unit for correct installation (whether it is secured in position).
 - Check the open/close operation of the right door.
 - Check the fusing unit-MFPB CN22E for proper connection and correct or change as necessary. (bizhub 558)
 - Check the fusing unit-MFPB CN12E for proper connection and correct or change as necessary. (bizhub 458)
 - Check the connector between TEMS/1-relay CN109-MFPB CN15E for proper connection and correct as necessary. (bizhub 558)
 - Replace the fusing unit. (bizhub 558 Part# A9E8030 / bizhub 458 Part# A79MR70200)
 - Replace IHPU. (bizhub 558 only)(Part# A8KNM40A02)
 - Replace FUPU. (bizhub 458 only) (Part# A79MM40N00)
 - Replace MFPB. (558 Part# A9HGH02102 / 458 Part# A9HHH02102)
 
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.13.6 (Link to the Field Service Manual)
