C3726 (bizhub C3320i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
| Trouble type | C3726: Fusing abnormally high temperature detection (Center of the heating roller) | 
| Rank | A | 
| Trouble detection condition | Detected temperature of the heating roller thermistor/Ctr (TH2) goes beyond a given temperature for a given period of time consecutively. | 
| Trouble isolation | – | 
| Relevant electrical parts | -Fusing unit -Heating roller thermistor/Edg (TH1) -DC power supply (DCPS) -CPU board (CPUB) -Base board (BASEB)  | 
Procedure
- Check the fusing unit for correct installation (whether it is secured in position).
 - Check the open/close operation of the right door.
 - Check the connector between the fusing unit-relay CN3-BASEB CN10E for proper connection and correct as necessary.
 - Check the connector between the fusing unit-relay CN2-DCPS CN2 for proper connection and correct as necessary.
 - Check CPUB for proper installation and correct as necessary.
 - Replace the fusing unit. (Part# AAJRR70300)
 - Replace CPUB. (Part# AAJRH01005)
 - Replace BASEB. (Part# A93EH02007)
 - Replace DCPS. (Part# AAJRR70600)
 
L.3.8.3 (Link to the Field Service Manual)