C3726 (bizhub C368/C308/C258)
Contents
Trouble type | C3726: Fusing abnormally high temperature detection (Center of the heating roller) |
Rank | A |
Trouble detection condition | Detected temperature of the heating roller thermistor/2 (TH2) goes beyond a given temperature for a given period of time consecutively. |
Trouble isolation | – |
Relevant electrical parts | • Fusing unit • Heating roller thermistor/2 (TH2) • MFP board (MFPB) |
Procedure
- Check the fusing unit for correct installation (whether it is secured in position).
- Check the open/close operation of the right door.
- Check the fusing unit and MFPB for proper connection and correct or change as necessary.
- Replace the fusing unit. (Part# A161R71888)
- Replace MFPB. (Part# A7PUH02123)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.13.5 (Link to the Field Service Manual)