Trouble typeC3731: Fusing abnormally high temperature detection (hard protector)
RankA
Trouble detection conditionThe hard protector signal malfunction is detected for a predetermined continuous period of time or more.
Trouble isolation
Relevant electrical parts• Fusing unit
• Heating roller thermistor/Edg (TH1)
• Heating roller temperature sensor (TEMS)
• Heating roller thermistor/Ctr (TH2)
• DC power supply (DCPS)
• CPU board (CPUB)
• Base board (BASEB)

Procedure

  1. Check the fusing unit for correct installation (whether it is secured in position).
  2. Check the open/close operation of the right door.
  3. Check the connector between the fusing unit-relay CN3-BASEB CN10E for proper connection and correct as necessary.
  4. Check the connector between the fusing unit-relay CN2-DCPS CN2 for proper connection and correct as necessary.
  5. Check CPUB for proper installation and correct as necessary.
  6. Replace the fusing unit. (Part# AAJRR70300)
  7. Replace CPUB. (Part# AAJRH01005)
  8. Replace BASEB. (Part# AAJRH02005)
  9. Replace DCPS. (Part# AAJRR70600)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.