C3736 (bizhub 558/458)
Contents
Trouble type | C3736: Fusing abnormally high temperature detection hard protector (Middle of the heating side) |
Rank | A |
Trouble detection condition | An abnormally high temperature is detected on the hard protector circuit (middle of the heating side). |
Trouble isolation | – |
Relevant electrical parts | • Fusing unit • Heating roller thermistor 2 (TH2) • IH power supply (IHPU) (bizhub 558 only) • MFP board (MFPB) |
Procedure
- Check the fusing unit for correct installation (whether it is secured in position).
- Check the open/close operation of the right door.
- Check the fusing unit-MFPB CN22E for proper connection and correct or change as necessary. (bizhub 558)
- Check the fusing unit-MFPB CN12E for proper connection and correct or change as necessary. (bizhub 458)
- Check the connector between TEMS/1-relay CN109-MFPB CN15E for proper connection and correct as necessary. (bizhub 558)
- Replace the fusing unit. (bizhub 558 Part# A9E8030 / bizhub 458 Part# A79MR70200)
- Replace IHPU. (bizhub 558 only)(Part# A8KNM40A02)
- Replace MFPB. (558 Part# A9HGH02102 / 458 Part# A9HHH02102)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.13.7 (Link to the Field Service Manual)