C3737 (bizhub 658e/558e/458e)
Contents
Trouble type | C3737: Fusing abnormally high temperature detection hard protector (Center of the heating roller) |
Rank | A |
Trouble detection condition | An abnormally high temperature is detected on the hard protector circuit (center of the heating roller). |
Trouble isolation | – |
Relevant electrical parts | • Fusing unit • (bizhub 658e/558e): Heating roller temperature sensor/1 (TEMS/1), (bizhub 458e): Heating roller temperature sensor (TEMS) • IH power supply (IHPU) (bizhub 658e/558e only) • MFP board (MFPB) |
Procedure
- Check the fusing unit for correct installation (whether it is secured in position).
- Check the open/close operation of the right door.
- Check the fusing unit-MFPB CN22E for proper connection and correct or change as necessary. (bizhub 658e/558e)
- Check the fusing unit-MFPB CN12E for proper connection and correct or change as necessary. (bizhub 458e)
- Check the connector between TEMS/1-relay CN109-MFPB CN15E for proper connection and correct as necessary. (bizhub 658e/558e only)
- Check the connector between TEMS/2-relay CN138-MFPB CN15E for proper connection and correct as necessary. (bizhub 658e only)
- Replace the fusing unit. (bizhub 658e/558e Part# A79JR71077 / bizhub 458e Part# AA6UR70400)
- Replace IHPU. (bizhub 658e/558e only) (Part# A8KNM40A02)
- Replace MFPB. (658e/558e Part# AA6RH02103 / 458e Part# AA6UH02101)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.12.7 (Link to the Field Service Manual)