Trouble type– C3822: Fusing abnormally low temperature detection (edge of the heating roller)

– C3825: Fusing abnormally low temperature detection (main of the heating roller)

– C3826: Fusing abnormally low temperature detection (middle of the heating roller)
RankA
Trouble detection condition– C3822: Detected temperature of the heating roller thermistor/Edg (TH1) goes under a given temperature for a given period of time consecutively.

– C3822: Detected temperature of the heating roller temperature sensor/2 (RD2) goes under a given temperature for a given period of time consecutively.C3825: Detected temperature of the heating roller temperature sensor/1 (RD1) goes under a given temperature for a given period of time consecutively.

– C3826: Detected temperature of the heating roller thermistor/Ctr (TH2) goes under a given temperature for a given period of time consecutively.
Trouble isolation
Relevant electrical parts– Fusing unit
– C3822: Heating roller thermistor/Edg (TH1)
– C3822: Heating roller temperature sensor/2 (RD2)
– C3825: Heating roller temperature sensor/1 (RD1)
– C3826: Heating roller thermistor/Ctr (TH2)
– CPU board (CPUB)
– Base board (BASEB)

Procedure

  1. Check the fusing unit for correct installation (whether it is secured in position).
  2. Check the open/close operation of the right door.
  3. Check the connector between the fusing unit-relay CN807-BASEB CN30E for proper connection and correct as necessary.
  4. Check CPUB for proper installation and correct as necessary.
  5. Replace the fusing unit.
  6. Replace CPUB.
  7. Replace BASEB.