How Can We Help?

C3823 (bizhub 958/808)

You are here:

Contents

Trouble
type
C3823: Fusing abnormally low temperature detection (pressure)
RankA
Trouble
detection condition
Detected temperature of the pressure roller thermistor/2 (TH3)
goes
beyond a given temperature for a given period of time
consecutively.
Trouble
isolation
Relevant
electrical
parts
• Fusing unit
• Pressure roller thermistor/2 (TH3)
• IH power supply unit (IHPU)
• Noise filter (NF1)
• Pressure roller power supply unit (PRPU)
• MFP board (MFPB)

 Procedure

  1. Check the fusing unit for correct installation (whether it is secured in position).
  2. Check the open/close operation of the upper right door.
  3. Check the fusing unit-MFPB CN30E for proper connection and correct or change as necessary.
  4. Check the connector between NF1 CN2-IHPU CN1 for proper connection and correct as necessary.
  5. Check the connector between IHPU CN8-MFPB CN18E for proper connection and correct as necessary.
  6. Replace the fusing unit. ( 958)A796R71422 )( 808)A795R72922 )
  7. Replace IHPU. (958)( A796M40B00 )(808)( A8KNM40A02 )
  8. MFPB IC80E conduction check
  9. Replace PRPU. ( A796M40500 )
  10. Replace MFPB. ( A796H02003)
  11. Replace NF1. (958)( A796M40H00 )(808)( A795M40J00 )

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

(Link to the Field Service Manual) K.3.9.16. 

Table of Contents