C3823 (bizhub 958/808)

You are here:

Contents

Trouble
type
C3823: Fusing abnormally low temperature detection (pressure)
RankA
Trouble
detection condition
Detected temperature of the pressure roller thermistor/2 (TH3)
goes
beyond a given temperature for a given period of time
consecutively.
Trouble
isolation
Relevant
electrical
parts
• Fusing unit
• Pressure roller thermistor/2 (TH3)
• IH power supply unit (IHPU)
• Noise filter (NF1)
• Pressure roller power supply unit (PRPU)
• MFP board (MFPB)

 Procedure

  1. Check the fusing unit for correct installation (whether it is secured in position).
  2. Check the open/close operation of the upper right door.
  3. Check the fusing unit-MFPB CN30E for proper connection and correct or change as necessary.
  4. Check the connector between NF1 CN2-IHPU CN1 for proper connection and correct as necessary.
  5. Check the connector between IHPU CN8-MFPB CN18E for proper connection and correct as necessary.
  6. Replace the fusing unit. ( 958)A796R71422 )( 808)A795R72922 )
  7. Replace IHPU. (958)( A796M40B00 )(808)( A8KNM40A02 )
  8. MFPB IC80E conduction check
  9. Replace PRPU. ( A796M40500 )
  10. Replace MFPB. ( A796H02003)
  11. Replace NF1. (958)( A796M40H00 )(808)( A795M40J00 )

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

(Link to the Field Service Manual) K.3.9.16.