How Can We Help?

C3825, C3826 (bizhub C750i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC3825: Fusing abnormally low temperature detection (Main of the heating roller)

C3826: Fusing abnormally low temperature detection (Center of the heating roller)
RankA
Trouble detection conditionC3825: The heating roller temperature sensor (TEMS) continues to detect a temperature lower than a predetermined one for a predetermined period of time.

C3826: The heating roller thermistor/Ctr (TH2) continues to detect a temperature lower than a predetermined one for a predetermined period of time.
Trouble isolation
Relevant electrical parts-Fusing unit

-C3825: Heating roller temperature sensor (TEMS) or C3826: Heating roller thermistor/Ctr (TH2)

-CPU board (CPUB)
-Base board (BASEB)

Procedure

  1. Check the fusing unit for correct installation (whether it is secured in position).
  2. Check the open/close operation of the right door.
  3. Check the connector between the fusing unit-relay CN95-BASEB CN4E for proper connection and correct as necessary.
  4. Check CPUB for proper installation and correct as necessary.
  5. Replace the fusing unit. (Part# AA7NR70200)
  6. Replace CPUB. (Part# ACKNH02P03)
  7. Replace BASEB. (Part# ACKNH02101)

(Link to the Field Service Manual)

Table of Contents