C3825: Fusing abnormally low temperature detection (Main of the heating roller)C3826: Fusing abnormally low temperature detection (Center of the heating roller)
Rank
A
Trouble detection condition
C3825: The heating roller temperature sensor (TEMS) continues to detect a temperature lower than a predetermined one for a predetermined period of time.C3826: The heating roller thermistor/Ctr (TH2) continues to detect a temperature lower than a predetermined one for a predetermined period of time.
Trouble isolation
–
Relevant electrical parts
Fusing unitC3825: Heating roller temperature sensor (TEMS)C3826: Heating roller thermistor/Ctr (TH2)DC power supply (DCPS)CPU board (CPUB)Base board (BASEB)
Procedure
Check the fusing unit for correct installation (whether it is secured in position).
Check the open/close operation of the right door.
Check the connector between the fusing unit-relay CN3-BASEB CN10E for proper connection and correct as necessary.
Check the connector between the fusing unit-relay CN2-DCPS CN2 for proper connection and correct as necessary.
Check CPUB for proper installation and correct as necessary.