Contents
Trouble type | Thermostat tripping |
Trouble code | C3903 |
Rank | A |
Detection timing | During warm-up, the thermostat tripping detection signal continues to be H for the set period of time. |
Trouble isolation | – |
Relevant electrical parts | • Fusing unit • Heating roller thermostat (TS1) • IH power supply (IHPU) • Noise filter (NF1) • Printer control board (PRCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the fusing unit for correct installation (whether it is secured in position). | – | – |
2 | Check the open/close operation of the upper right door. | – | – |
3 | Check the fusing unit, IHPU, NF1 and PRCB for proper connection and correct or change as necessary. | – | – |
4 | Replace the fusing unit (Other area except Taiwan/Only for Taiwan) (Part# A2X0R71055) | – | – |
5 | Replace IHPU (Part# A2X0R71055) | – | – |
6 | Replace PRCB (Part# A55VH00105) | – | – |
7 | Replace NF1 (Part# A2XKM40J00) | – | – |
- Link to the layout drawings for related parts by each trouble code (S.72. C3722, C3726, C3822, C3903, C3922, C3926 (Other area except Taiwan))
- Link to the layout drawings for related parts by each trouble code (S.73. C3722, C3726, C3822, C3903, C3922, C3926 (Only for Taiwan))