Trouble type | C3922: Fusing sensor wire breaks detection (Edge of the heating roller) |
Rank | A |
Trouble detection condition | The maximum value and minimum value of detected temperature of the heating roller thermistor/Edg (TH1) is compared after a lapse of given time from starting of warm up and the gap between the value of maximum and minimum is below a given temperature. |
Trouble isolation | – |
Relevant electrical parts | -Fusing unit -Heating roller thermistor/Edg (TH1) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Check the fusing unit for correct installation (whether it is secured in position).
- Check the open/close operation of the right door.
- Check the connector between the fusing unit-relay CN95-BASEB CN4E for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Replace the fusing unit. (C650i/C550i Part# AA7NR70200 / C450i Part# AA7RR70700)
- Replace CPUB. (C450i Part# AA7RH02P02 / C550i Part# AA7PH02P01 / C650i Part# AA7NH02P03)
- Replace BASEB. (Part# AA7NH02102)