How Can We Help?

C3922, C3925, C3926 (bizhub 750i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC3922: Fusing sensor wire breaks detection (Edge of the heating roller)

C3925: Fusing sensor wire breaks detection (Main of the heating roller)

C3926: Fusing sensor wire breaks detection (Center of the heating roller)
RankA
Trouble detection conditionC3922: The maximum value and minimum value of detected temperature of the heating roller thermistor/Edg (TH1) is compared after a lapse of given time from starting of warm up and the gap between the value of maximum and minimum is below a given temperature.

C3925: The maximum value and minimum value of detected temperature of the heating roller temperature sensor (TEMS) is compared after a lapse of given time from starting of warm up and the gap between the value of maximum and minimum is below a given temperature.

C3926: The maximum value and minimum value of detected temperature of the heating roller thermistor/Ctr (TH2) is compared after a lapse of given time from starting of warm up and the gap between the value of maximum and minimum is below a given temperature.
Trouble isolation
Relevant electrical parts-Fusing unit

-C3922: Heating roller thermistor/Edg (TH1), or C3925: Heating roller temperature sensor (TEMS), or C3926: Heating roller thermistor/Ctr (TH2)

-CPU board (CPUB)
-Base board (BASEB)

Procedure

  1. Check the fusing unit for correct installation (whether it is secured in position).
  2. Check the open/close operation of the right door.
  3. Check the connector between the fusing unit-relay CN95-BASEB CN4E for proper connection and correct as necessary.
  4. Check CPUB for proper installation and correct as necessary.
  5. Replace the fusing unit. (Part# AA7NR70200)
  6. Replace CPUB. (Part# ACV7H02P02)
  7. Replace BASEB. (Part# ACV7H02101)

(Link to the Field Service Manual)

Table of Contents