C3926 (bizhub C3320i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
| Trouble type | C3926: Fusing sensor wire breaks detection (Center of the heating roller) | 
| Rank | A | 
| Trouble detection condition | The maximum value and minimum value of detected temperature of the heating roller thermistor/Ctr (TH2) is compared after a lapse of given time from starting of warm up and the gap between the value of maximum and minimum is below or above given temperatures. | 
| Trouble isolation | – | 
| Relevant electrical parts | -Fusing unit -Heating roller thermistor/Ctr (TH2) -DC power supply (DCPS) -CPU board (CPUB) -Base board (BASEB)  | 
Procedure
- Check the fusing unit for correct installation (whether it is secured in position).
 - Check the open/close operation of the right door.
 - Check the connector between the fusing unit-relay CN3-BASEB CN10E for proper connection and correct as necessary.
 - Check the connector between the fusing unit-relay CN2-DCPS CN2 for proper connection and correct as necessary.
 - Check CPUB for proper installation and correct as necessary.
 - Replace the fusing unit. (Part# AAJRR70300)
 - Replace CPUB. (Part# AAJRH01005)
 - Replace BASEB. (Part# A93EH02007)
 - DCPS F102 or FU181 conduction check.
 - Replace DCPS. (Part# AAJRR70600)
 
L.3.8.6 (Link to the Field Service Manual)