Trouble typeC3926: Fusing sensor wire breaks detection (Center of the heating roller)
RankA
Trouble detection conditionThe maximum value and minimum value of detected temperature of the heating roller thermistor/Ctr (TH2) is compared after a lapse of given time from starting of warm up and the gap between the value of maximum and minimum is below a given temperature.
Trouble isolation
Relevant electrical parts• Fusing unit
• Heating roller thermistor/Ctr (TH2)
• CPU board (CPUB)
• Base board (BASEB)

Procedure

  1. Check the fusing unit for correct installation (whether it is secured in position).
  2. Check the open/close operation of the right door.
  3. Check the connector between the fusing unit-relay CN95-BASEB CN4E for proper connection and correct as necessary.
  4. Check CPUB for proper installation and correct as necessary.
  5. Replace the fusing unit. (Part# AA2JR70300)
  6. Replace CPUB. (Part# AA2JH02N06)
  7. Replace BASEB. (Part# AA2JH02005)