C3926 (bizhub C364e/C284e/C224e)

You are here:

Contents

Trouble typeFusing sensor wire breaks detection (Middle of the heating roller)
Trouble codeC3926
RankA
Detection timing• After a predetermined period of time after the warm-up stage is started, the heating roller thermistor/2 (TH2) voltage does not decrease by predetermined steps (temperature rise) within a predetermined time.
• When a temperature detected by the heating roller thermister/1 (TH1) is compared with the temperature detected by the heating roller thermister/2 (TH2) to find out that the difference exceeded the predetermined temperature.
Trouble isolation
Relevant electrical parts• Fusing unitHeating roller thermistor/1 (TH1)
• Heating roller thermistor/2 (TH2)
• Printer control board (PRCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the fusing unit for correct installation (whether it is secured in position).
2Check the open/close operation of the upper right door.
3Check the fusing unit and PRCB for proper connection and correct or change as necessary.
4Replace the fusing unit (Part# A161R71866)
5Replace PRCB (Part# A5C1H00102)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.8.7 (L ink to the Field Service Manual)