C3926 (bizhub C4050i/C3350i)
Contents
Trouble type | C3926: Fusing sensor wire breaks detection (Center of the heating roller) |
Rank | A |
Trouble detection condition | C3926: The maximum value and minimum value of detected temperature of the heating roller thermistor/Ctr (TH2) is compared after a lapse of given time from starting of warm up and the gap between the value of maximum and minimum is below or above given temperatures. |
Trouble isolation | – |
Relevant electrical parts | • Fusing unit • C3926: Heating roller thermistor/Ctr (TH2) • DC power supply (DCPS) • CPU board (CPUB) • Base board (BASEB) |
Procedure
- Check the fusing unit for correct installation (whether it is secured in position).
- Check the open/close operation of the right door.
- Check the connector between the fusing unit-relay CN3-BASEB CN10E for proper connection and correct as necessary.
- Check the connector between the fusing unit-relay CN2-DCPS CN2 for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Replace the fusing unit. (Part# AAJRR70300)
- Replace CPUB. (Part# A93EH01004)
- Replace BASEB. (Part# A93EH02007)
- DCPS F102 or FU181 conduction check.
- Replace DCPS. (Part# AAJRR70600)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.8.6 (Link to the Field Service Manual)