How Can We Help?

C3926 (bizhub C759/C659)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC3926: Fusing sensor wire breaks detection (Center of the heating roller)
RankA
Trouble detection conditionThe maximum value and minimum value of detected temperature of the heating roller temperature sensor/3 (TEMS3) is compared after a lapse of given time from starting of warm up and the gap between the value of maximum and minimum is below a given temperature.
Trouble isolation
Relevant electrical parts-Fusing unit
-Heating roller temperature sensor/3 (TEMS3)
-MFP board (MFPB)

 Procedure

  1. Check the fusing unit for correct installation (whether it is secured in position).
  2. Check the open/close operation of the upper right door.
  3. Check the connector between TEMS1, TEMS2, TEMS3-relay CN512-MFPB CN31E for proper connection and correct as necessary.
  4. Replace the fusing unit. (Part# A8JER70222)
  5. MFPB F3E conduction check
  6. Replace MFPB. (Part# A8JEH02002)

L.3.10.13 (Link to the Field Service Manual)