How Can We Help?

C392A (bizhub 658e/558e)

You are here:

Contents

Trouble typeC392A: Heating roller temperature sensor contamination (Main of the heating roller) (bizhub 658e/558e)
RankC
Trouble detection conditionDuring waiting after a predetermined period of time after the warm-up stage terminates, the temperature detected by the heating roller thermistor/3 (TH3) exceeds that detected by the heating roller temperature sensor/1 (TEMS/1) above a predetermined temperature, and this state continues for a predetermined period of time.
Trouble isolation
Relevant electrical parts• Fusing unitHeating roller temperature sensor/1 (TEMS/1)
• Heating roller thermistor/3 (TH3)
• MFP board (MFPB)

 Procedure

  1. Wipe the TEMS/1 clean of dirt if any.
  2. <Cleaning procedure>
    • Clear away a dirt or a foreign object on the sensor with a cotton swab.
    • When a dirt is left even if you cleaned the sensor by above procedure, clear away a dirt or a foreign object on the sensor using a cotton swab dampened with the alcohol. And, wipe off the sensor with a dry cotton swab afterwards.
  3. Check the TEMS/1 for installed position and proper connector connection.
  4. Check the connection of the fusing unit.
  5. Check the fusing unit-MFPB CN22E for proper connection and correct or change as necessary.
  6. Check the connector between TEMS/1-relay CN109-MFPB CN15E for proper connection and correct as necessary.
  7. Replace the fusing unit. (Part# A79JR71077)
  8. Replace MFPB. (Part# AA6RH02103)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.12.10 (Link to the Field Service Manual)

Table of Contents