C392B (bizhub 368e/308e)

You are here:

Contents

Trouble typeC392B: Fusing sensor wire breaks detection (difference of temperature)
RankA
Trouble detection conditionThe difference between the temperature corrected by the heating roller thermistor/1 (TH1) and the temperature detected by the heating roller thermistor/2 (TH2) exceeds a predetermined value.
Trouble isolation
Relevant electrical parts• Fusing unit
• Heating roller thermistor/1 (TH1)
• Heating roller thermistor/2 (TH2)
• MFP board (MFPB)

 Procedure

  1. Check the fusing unit for correct installation (whether it is secured in position).
  2. Check the open/close operation of the right door.
  3. Check the fusing unit and MFPB for proper connection and correct or change as necessary.
  4. Replace the fusing unit. (Part# A79JR71033)
  5. Replace MFPB. (Part# AA6VH02101)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.11.9 (Link to the Field Service Manual)