C392B (bizhub C650i/C550i/C450i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
| Trouble type | C392B: Fusing sensor wire breaks detection (difference of temperature) | 
| Rank | A | 
| Trouble detection condition | The difference between the temperature corrected by the heating roller thermistor/Edg (TH1) and the temperature detected by the heating roller thermistor/Ctr (TH2) exceeds a predetermined value. | 
| Trouble isolation | – | 
| Relevant electrical parts | -Fusing unit -Heating roller thermistor/Edg (TH1) -Heating roller thermistor/Ctr (TH2) -CPU board (CPUB) -Base board (BASEB)  | 
Procedure
- Check the fusing unit for correct installation (whether it is secured in position).
 - Check the open/close operation of the right door.
 - Check the connector between the fusing unit-relay CN95-BASEB CN4E for proper connection and correct as necessary.
 - Check CPUB for proper installation and correct as necessary.
 - Replace the fusing unit. (C650i/C550i Part# AA7NR70200 / C450i Part# AA7RR70700)
 - Replace CPUB. (C450i Part# AA7RH02P02 / C550i Part# AA7PH02P01 / C650i Part# AA7NH02P03)
 - Replace BASEB. (Part# AA7NH02102)
 
L.3.10.13 (Link to the Field Service Manual)