How Can We Help?

C3B03 (bizhub C754/C654)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeIH malfunction (monitor)
Trouble codeC3B03
RankA
Detection timing-Though the IH heater is ON, this status cannot be detected mechanically. (IH heater operation failure)
-Though the IH heater is OFF, mechanically, the ON status is detected. (Malfunction of IH heater operation)
Trouble isolation
Relevant electrical parts-Fusing unit
-IH coil unit (FH1)
-IH magnetic erasing board (IHMEB)
-Noise filter (NF1)
-Printer control board (PRCB)

(2)Procedure

StepActionControl signalLocation of electrical components
1Check the fusing unit for correct installation (whether it is secured in position).
2Check the open/close operation of the upper right door.
3Check the fusing unit, IH coil unit, IHPU, IHMEB, NF1 and PRCB for proper connection and correct or change as necessary.
4Replace the fusing unit (Part# A2X0R71011)
5Replace the IH coil unit (Part# A2X0M40200)
6Replace IHPU (Part# A61DM40A00)
7Replace IHMEB (Part# A2X0H00W02)
8PRCB ICP5 conduction check
9Replace PRCB (Part# A2X0H00102)
10Replace NF1 (Part# A2XKM40J00)

K.3.8.12 (Link to the Field Service Manual)