C3B07 (bizhub C554/C454)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeIH input power error
Trouble codeC3B07
RankA
<bizhub C554>
-While the IH heater was ON, input power stayed at the high voltage power detection value or over for more than the predetermined period of time.
-While the IH heater was ON, input power was at the low power detection value or under for more than the predetermined period of time.
-While the IH heater was ON, input power was at the high voltage detection value or over for more than the predetermined period of time.
-While the IH heater was ON, input power was below the low voltage detection value or under for more than the predetermined period of time.
-While the IH heater was ON, inverter power stayed at the upper limit value or over for more than the predetermined period of time.
-While the IH heater was ON, output voltage halt was detected.
Detection timing
Trouble isolation
Relevant electrical parts-IH coil unit (IHC)
-IH power supply (IHPU)
-Printer control board (PRCB)

(2)Procedure

StepActionControl signalLocation of electrical components
1Check the connection of the fusing unit.
2Check the fusing unit, IHC, IHPU and PRCB for proper connection and correct or change as necessary.
3Replace IHC (Part# A2XKM40C01)
4Replace IHPU (Part# A61DM40A00)
5Replace PRCB (Part# A2XKH00104)

K3.8.12 (Link to the Field Service Manual)