C3B08 (bizhub 558/458)
Contents
Trouble type | C3B08: IH input voltage error (bizhub 558) |
Rank | B |
Trouble detection condition | • While the IH heater was ON, input power was at the high voltage detection value or over for more than the predetermined period of time. • While the IH heater was ON, input voltage was at the low power detection value or under for more than the predetermined period of time. |
Trouble isolation | – |
Relevant electrical parts | • Fusing unit • IH coil (IHC) • IH power supply (IHPU) • NF board (NFB) • MFP board (MFPB) |
Procedure
- Check the fusing unit for correct installation (whether it is secured in position).
- Check the fusing unit-MFPB CN22E for proper connection and correct or change as necessary.
- Check the connector between NFB CN2-IHPU CN1 for proper connection and correct as necessary.
- Check the connector between IHPU CN8-MFPB CN3E for proper connection and correct as necessary.
- Check the marketing area of the fusing unit. If the marketing area is incorrect, replace the fusing unit for proper marketing area.
- Check the marketing area of IHPU. If the marketing area is incorrect, replace IHPU for proper marketing area.
- Replace IHC. (558)(Part# A79KM40C00)
- Replace IHPU. (558)(Part# A8KNM40A02)
- Replace MFPB. (558 Part# A9HGH02102 / 458 Part# A9HHH02102)
- Replace NFB. (558)(Part# A795M40J00)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.13.13 (Link to the Field Service Manual)