Trouble type PH communication error
Trouble code C4002
Rank C
Detection timing When the PH relay board (PHRYB) is receiving data, a communication error is detected.
Trouble isolation
Relevant electrical parts • PH relay board (PHRYB)
• Printer control board (PRCB)

  (2)Procedure

Step Action Control signal Location of electrical components
1 Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch.
2 PRCB ICP17 conduction check
3 Replace PRCBPRCB (Part# A55VH00105)
4 PHRYB ICP2 conduction check
5 Replace PHRYBPHRYB (Part# A55VH00300)
  • Link to the layout drawings for related parts by each trouble code (S.78. C4002)