How Can We Help?

C4002 (bizhub C754/C654)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typePH communication error
Trouble codeC4002
RankC
Detection timingWhen the PH relay board (PHRYB) is receiving data, a communication error is detected.
Trouble isolation
Relevant electrical parts-PH relay board (PHRYB)
-Printer control board (PRCB)

(2)Procedure

StepActionControl signalLocation of electrical components
1Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch.
2PRCB ICP17 conduction check
3Replace PRCB (Part# A2X0H00102)
4PHRYB ICP1 conduction check
5Replace PHRYB (Part# A2X0H00300)
  • Link to the layout drawings for related parts by each trouble code (S.77. C4002)

K.3.9.1 (Link to the Field Service Manual)

Table of Contents