C40A2, C40A3, C40A4, C40A5, C40A6, C40C3, C40C5 (bizhub 750i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC40A2: Mechanical controller PF communication data error

C40A3: Mechanical controller PF transmission timeout

C40A4: Mechanical controller PF communication pulse error

C40A5: QSPI communication clock switching error

C40A6: Mechanical controller ASIC communication error

C40C3: CTL PF transmission timeout 1

C40C5: CTL PF transmission timeout 2
RankC
Trouble detection conditionA CPU communication error is detected.
Trouble isolation
Relevant electrical parts-CPU board (CPUB)
-Base board (BASEB)

Procedure

  1. Turn OFF the main power switch and unplug the power cord. Connect the power cord after 15 sec. or more, and turn ON the main power switch.
  2. Check CPUB for proper installation and correct as necessary.
  3. Rewrite the firmware.
  4. Replace CPUB. (Part# ACV7H02P02)
  5. BASEB F8E conduction check
  6. Replace BASEB. (Part# ACV7H02101)

(Link to the Field Service Manual)