C40A3 (bizhub C3320i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C40A3: Mechanical controller PF transmission timeout |
Rank | C |
Trouble detection condition | A CPU communication error is detected. |
Trouble isolation | – |
Relevant electrical parts | -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Turn OFF the main power switch and unplug the power cord. Connect the power cord after 15 sec. or more, and turn ON the main power switch.
- Check CPUB for proper installation and correct as necessary.
- Rewrite the firmware.
- Replace CPUB. (Part# AAJRH01005)
- BASEB F15E and PTC2E conduction check
- Replace BASEB. (Part# A93EH02007)
L.3.9.2 (Link to the Field Service Manual)