Contents
Trouble type | C40C5: CTL PF transmission timeout 2 |
Rank | C |
Trouble detection condition | A CPU communication error is detected. |
Trouble isolation | – |
Relevant electrical parts | -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Turn OFF the main power switch and unplug the power cord. Connect the power cord after 15 sec. or more, and turn ON the main power switch.
- Check CPUB for proper installation and correct as necessary.
- Rewrite the firmware.
- Replace CPUB. (C450i Part# AA7RH02P02 / C550i Part# AA7PH02P01 / C650i Part# AA7NH02P03)
- BASEB F8E conduction check
- Replace BASEB. (Part# AA7NH02102)