How Can We Help?

C4301 (bizhub 754e/654e)

You are here:

Contents

Trouble type PH cooling fan failure to turn
Trouble code C4301
Rank B
Detection timing The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts• PH cooling fan (FM14)
• PH relay board (PHRYB)
• Printer control board (PRCB)

  (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between FM14-relay CN202-PHRYB CN12 for proper connection and correct as necessary.
2Check the fan for possible overload and correct as necessary.
3FM14 operation checkPHRYB CN12-8 (DRIVE)PHRYB CN12-9 (LOCK)9-B
4Replace FM14 (Part# 9J03M10000)
5PHRYB ICP1 conduction check
6Replace PHRYB (Part# A55VH00300)
7Replace PRCB (Part# A55VH00105)

Document Information ID D0001104790 Revise ID R000003