Trouble typeC5103: Transport motor turning at abnormal timing
RankB
Trouble detection conditionThe motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Trouble isolation
Relevant electrical parts-Transport motor (M1)
-MFP board (MFPB)

 Procedure

  1. Check the connector between M1-MFPB CN19E for proper connection and correct as necessary.
  2. Check the loading status of the transfer roller drive, and correct the error as necessary.
  3. M1 operation check
    • Control signal: MFPB CN19E-3 to 7
    • Location of electrical component: 26-C
  4. Replace M1. (Part# A61DM10200)
  5. MFPB F10E conduction check
  6. Replace MFPB. (Part# A7AHH0201D)