C5105 (bizhub C759/C659)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C5105: Transfer belt motor turning at abnormal timing |
Rank | B |
Trouble detection condition | The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary. |
Trouble isolation | – |
Relevant electrical parts | -Transfer belt unit -Transfer belt motor (M1) -MFP board (MFPB) |
Procedure
- Check the connector between M1-MFPB CN10E, CN16E for proper connection and correct as necessary.
- Check the loading status of the transfer belt drive, and correct the error as necessary.
- Check the drive gear of the transfer belt unit for rotation and correct any faulty rotation.
- M1 load check
- Check code: 46
- Multi code: 1, 2, 3, 4
- Control signal: MFPB CN10E<A>-3 (REM), MFPB CN10E<A>-6 (LOCK), MFPB CN16E-7 (DC24V), MFPB CN10E<A>-2 (DC3.3V)
- Location of electrical component: 5-K
- Replace M1. (Part# A00JM11300)
- Replace the transfer belt unit. (Part# A8JER70111)
- MFPB F2E or F11E conduction check
- Replace MFPB. (Part# A8JEH02002)
L.3.12.1 (Link to the Field Service Manual)