How Can We Help?

C5304 (bizhub 554e/454e)

You are here:

Contents

Trouble typeFusing power supply cooling fan’s failure to turn
Trouble codeC5304
RankB
Detection timing<bizhub 554e>
The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts• Fusing power supply cooling fan (FM12)
• Expansion control board (EXCB)
• Printer control board (PRCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between FM12-EXCB CN6 for proper connection and correct as necessary.
2Check the fan for possible overload and correct as necessary.
3FM12 operation checkEXCB CN6-1 (REM)EXCB CN6-3 (LOCK)23-T
4Replace FM12 (Part# 4139M10000)
5EXCB ICP1 conduction check
6Replace EXCB (Part# A5AYH00501)
7Replace PRCB (554e Part# A61EH00101 / 454e Part# A61DH00101)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.10.2 (Link to the Field Service Manual)

Table of Contents