C5304 (bizhub C754e/C654e)

You are here:

Contents

Trouble typeIH power supply cooling fan’s failure to turn
Trouble codeC5304
RankB
Detection timingThe fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts• IH power supply cooling fan (FM10)
• Printer control board (PRCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between FM10-relay CN293-PRCB CN5 for proper connection and correct as necessary.
2Check the fan for possible overload and correct as necessary.
3FM10 operation checkPRCB CN5-3 (DRIVE)PRCB CN5-5 (LOCK)9-K
4Replace FM10 (Part# 4556M10000)
5PRCB ICP24 conduction check
6Replace PRCB (Part# A2X0H00S06)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.10.2 (Link to the Field Service Manual)