C5351 (bizhub 554e/454e)
Contents
Trouble type | Power supply cooling fan motor’s failure to turn |
Trouble code | C5351 |
Rank | B |
Detection timing | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | • Power supply cooling fan (FM1) • Printer control board (PRCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between FM1-relay CN26-PRCB CN18 for proper connection and correct as necessary. | – | – |
2 | Check the fan for possible overload and correct as necessary. | – | – |
3 | FM1 operation check | PRCB CN18-13 (REM)PRCB CN18-15 (LOCK) | 7-C |
4 | Replace FM1 (Part# 4139M10000) | – | – |
5 | PRCB ICP2 conduction check | – | – |
6 | Replace PRCB (554e Part# A61EH00101 / 454e Part# A61DH00101) | – | – |
- Link to the wiring diagram (N.1. bizhub 554e/454e)
- Link to the layout drawings for related parts by each trouble code (S.88. C5351)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.10.4 (Link to the Field Service Manual)