Contents
Trouble type | C5351: PH/power supply cooling fan failure to turn |
Rank | B |
Trouble detection condition | The fan lock signal remains Low for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | -PH/power supply cooling fan (FM1) -Expansion control board (EXCB) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Check the connector between FM1-relay CN26-EXCB CN10EX for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- Check the connector between EXCB CN2EX-BASEB CN12E for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- FM1 load check
- Check code: 42
- Multi code: 1
- Control signal: EXCB CN10EX-6 (REM), EXCB CN10EX-8 (LOCK)
- Location of electrical component: 22-P
- Replace FM1. (Part# A93EM10000)
- Replace EXCB. (Part# AA7NH00500)
- Replace CPUB. (Part# ACKNH02P03)
- Replace BASEB. (Part# ACKNH02101)