C5351 (bizhub C754e/C654e)

You are here:

Contents

Trouble typeDC power supply cooling fan’s failure to turn
Trouble codeC5351
RankB
Detection timingThe fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts• DC power supply cooling fan (FM9)
• DC power supply (DCPU)
• Printer control board (PRCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between FM9-relay CN333-PRCB CN38 for proper connection and correct as necessary.
2Check the fan for possible overload and correct as necessary.
3FM9 operation checkPRCB CN38-1 (DRIVE)PRCB CN38-3 (LOCK)19-K
4Replace FM9 (Replace DCPU Fan Motor)
5PRCB ICP3 conduction check
6Replace DCPU (Part# A2X0R70311)
7Replace PRCB (Part# A2X0H00S06)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.10.4 (Link to the Field Service Manual)